Skip to product information
1 of 25

D-Link

48-Port 25GbE Layer 3 Data Center Switch with 8 × 100GbE QSFP28 Uplinks (DTS-5000-56S)

48-Port 25GbE Layer 3 Data Center Switch with 8 × 100GbE QSFP28 Uplinks (DTS-5000-56S)

Regular price $20,999.99 CAD
Regular price $20,999.99 CAD Sale price $20,999.99 CAD
Sale Sold out
Shipping calculated at checkout.
Quantity

Information on repairability and maintenance for Quebec consumers - Click Here

48 × 25GbE SFP28 ports and 8 × 100GbE QSFP28 uplinks in a 1RU platform for data center leaf and top-of-rack deployments, including micro data centers and enterprise server rooms

  • 25GbE Server Connectivity: 48 SFP28 downlink ports connect servers, storage and other network equipment
  • 100GbE Uplinks: Eight QSFP28 ports connect to aggregation and spine switches
  • Layer 3 Routing: BGP, OSPF and IS-IS support routed networks, with ECMP for multipath forwarding
  • Network Segmentation and Redundancy: EVPN and VXLAN support overlay networks, while MC-LAG supports redundant connections
  • Open Networking: Pre-installed ONIE enables installation of a supported SONiC network operating system
  • Management and Visibility: REST API and CLI support configuration and integration, while sFlow provides sampled traffic visibility
  • Priority-Based Flow Control: IEEE 802.1Qbb PFC provides flow control by traffic priority
  • Redundant Power and Cooling: Dual hot-swappable power supplies with 1+1 redundancy and four hot-swappable fans with N+1 redundancy
  • 1RU Rackmount Design: 440 × 470 × 44 mm chassis with front-to-back airflow
  • NDAA/TAA Sourcing Standards: Follows NDAA/TAA sourcing standards for public sector and enterprise projects
View full details
1 of 2

25GbE Layer 3 Data Center Switching with 100GbE Uplinks


The D-Link DTS-5000-56S is a compact 1RU Layer 3 switch for data center leaf and top-of-rack deployments. It can also provide central switching for servers and storage in micro data centers and enterprise server rooms. Its 48 × 25GbE SFP28 ports connect equipment at the rack, while eight 100GbE QSFP28 uplinks connect to the wider network.

The DTS-5000-56S follows NDAA/TAA sourcing standards for U.S. public-sector and enterprise deployments.

Applications

Data Center Leaf Networks • Top-of-Rack Deployments • Network Aggregation • Micro Data Centers • Enterprise Server Rooms

25GbE Server & Storage Connectivity

Connect servers and storage at the rack with 48 SFP28 ports supporting up to 25GbE per port

100GbE Uplinks

Carry traffic from the rack to spine or aggregation switches through eight QSFP28 uplinks supporting up to 100GbE per port

Layer 3 Routing

Route between networks with BGP, OSPF or IS-IS, and use ECMP to share traffic across equally preferred paths

Workload Segmentation

Use EVPN and VXLAN to keep workloads in separate logical networks while sharing the same switching infrastructure

Open Networking with SONiC

Deploy the SONiC image provided by D-Link using pre-installed ONIE, then configure it for your network

Redundant Power & Cooling

Help keep the switch running if a power supply or fan fails. Includes two hot-swappable power supplies (1+1) and four hot-swappable fans (N+1)

*Performance figures, port speeds, switching capacity and link distances are theoretical or specified maximums, as applicable. Actual results may vary with software version, configuration, connected equipment, transceivers, cabling, traffic patterns and operating conditions.

SONiC is an open-source network operating system. D-Link provides a SONiC image for the DTS-5000-56S. Your network team manages installation, configuration and ongoing operation to suit your environment. Available features and compatibility may vary by SONiC release and configuration. Refer to current product documentation or contact D-Link for information about the supplied image.

25GbE Connectivity with 100GbE Uplinks 

Connect servers and storage within the rack, then link to spine or aggregation switches through higher-speed uplinks.

The D-Link DTS-5000-56S combines 48 × 25GbE SFP28 ports and eight 100GbE QSFP28 uplinks in a 1RU design for leaf, top-of-rack and aggregation deployments.

Layer 3 Routing and Network Segmentation

Connect networks, distribute traffic across multiple routes and separate workloads into logical network segments. Redundant connections across compatible switches help reduce reliance on a single connection.

Data Center Traffic Management

Control traffic by priority and signal congestion so compatible systems can respond. RoCEv2 supports direct memory access between compatible servers and storage systems, with coordinated network and endpoint configuration.

Management and Visibility

Configure the switch through CLI and connect management tools through REST API. Review sampled traffic through sFlow and an external collector to understand network usage and investigate activity.

Open Networking with ONIE and SONiC 

The D-Link DTS-5000-56S comes with ONIE pre-installed to support network operating system installation. D-Link provides a SONiC image for the switch, giving network administrators an open-source software foundation for their deployment.

Network configuration is the responsibility of the network administrator. Contact D-Link to learn more about the supplied SONiC image, its supported features and how we can help with your deployment.

Redundant Power and Cooling Included 

The D-Link DTS-5000-56S includes two hot-swappable power supplies with 1+1 redundancy and four hot-swappable fans with N+1 redundancy.

The 1RU chassis uses front-to-back airflow for rack installations with front intake and rear exhaust. Hot-swappable modules support individual component replacement during maintenance while the remaining modules continue operating, following the applicable hardware procedures.

Technical Specifications

Take a closer look at the DTS-5000-56S. Open a category below to review ports, performance, software and installation details.

D-Link DTS-5000-56S data center switch

DTS-5000-56S

48-Port 25GbE Layer 3 Data Center Switch with 100GbE Uplinks

Designed For
Leaf / top-of-rack / aggregation
Applications
Server, storage and aggregation networks
Ports & Connectivity
Hardware revision C1
Designed For Leaf / top-of-rack / aggregation
Applications Server, storage and aggregation networks
Data ports 48 × SFP28, up to 25GbE
8 × QSFP28 uplinks, up to 100GbE
Ethernet standards IEEE 802.3ae, 802.3ba, 802.3bj, 802.3bm, 802.3by
Transceivers Sold separately. See the datasheet for compatible optics and direct-attach cables.
Management port 1 × 10/100/1000BASE-T RJ-45
Console / USB 1 × RJ-45 console for CLI management
1 × USB 2.0 Type A
Performance
Switching capacity Up to 2 Tbps
Full-duplex capacity Up to 4 Tbps
Packet forwarding rate Up to 2,800 Mpps
Packet buffer 24 MB
Switch silicon Marvell Falcon
CPU Marvell quad-core processor
System memory 8 GB DDR4
Storage 64 GB M.2 SATA
MAC address table Up to 128K entries
Static route scale Up to 288K IPv4 or 144K IPv6
Shared table resources
Software & Management
NOS / installation ONIE pre-installed
D-Link provides a SONiC image for installation
Routing highlights BGP IPv4/IPv6, OSPF, IS-IS, ECMP
Fabric features EVPN, VXLAN, MC-LAG
Flow control / RDMA IEEE 802.1Qbb PFC, ECN, RoCEv2
Management / visibility CLI, REST API, SNMP v1/v2c/v3, sFlow
Power & Installation
Power supplies 2 hot-swappable PSUs
1+1 redundancy
Power input 100–240 V AC or −36 to −72 V DC, depending on power supply configuration
Cooling 4 hot-swappable fans
N+1 redundancy
Airflow Front-to-back
Rack format 1RU / 19-inch rack
Dimensions (W × D × H) 17.32 × 18.50 × 1.73 in
(440 × 470 × 44 mm)
Weight 20.16 lb (9.146 kg)
Maximum power consumption Up to 312.6 W
Acoustics 36.9 dBA minimum / 79.6 dBA maximum
Operating temperature 32–113°F (0–45°C)
Operating humidity 5%–90% relative humidity
Storage temperature −40–158°F (−40–70°C)
Storage humidity 5%–95% relative humidity
Safety CE, UL
EMI FCC, BSMI
Sourcing Follows NDAA/TAA sourcing standards

Transceivers are sold separately. Software feature availability depends on the supported SONiC release and configuration. Contact D-Link for information about the supplied image and your deployment.

Optical Transceivers for the DTS-5000-56S

Shop single-mode and multimode optics for 25GbE SFP28 ports and 100GbE QSFP28 uplinks. Transceivers are sold separately from the switch.

25GbE SFP28

100GbE QSFP28

1 of 2

DTS-5000-56S Frequently Asked Questions

Where does the DTS-5000-56S fit in a data center network?

The DTS-5000-56S supports leaf, top-of-rack and aggregation deployments . Its 48 SFP28 ports support connections at up to 25GbE for servers, storage and other network equipment. Eight QSFP28 uplink ports support connections at up to 100GbE to spine and aggregation switches.

What is pre-installed, and what does ONIE provide?

ONIE is pre-installed to enable installation of a supported SONiC network operating system. ONIE provides the installation environment; the installed network operating system provides switching, routing and management functions. Use a SONiC image validated for this hardware platform.

Which routing and fabric features are supported?

Specified capabilities include BGP for IPv4 and IPv6, OSPF, IS-IS, ECMP multipath forwarding, EVPN/VXLAN overlays and MC-LAG for redundant connections. Feature availability depends on the supported SONiC release and configuration.

Does the switch support RoCEv2 and congestion management?

Specified capabilities include RoCEv2, IEEE 802.1Qbb Priority-Based Flow Control (PFC) and Explicit Congestion Notification (ECN) . RoCEv2 deployment requires compatible endpoints and coordinated network configuration. End-to-end behavior depends on the adapters, software, traffic priorities and congestion settings across the network.

How can I configure the switch and monitor traffic?

CLI and REST API support configuration and integration with management tools. sFlow provides sampled traffic visibility for an external collector. Available commands, API functions and monitoring capabilities depend on the supported software release.

Are dedicated management and console ports provided?

Yes. The switch includes a dedicated RJ-45 management port supporting connections at up to 1GbE, an RJ-45 console port for CLI access and a USB 2.0 Type-A port. These are separate from the SFP28 and QSFP28 data ports.

Are transceivers included with the switch?

Transceivers are sold separately. Order compatible SFP28 transceivers for 25GbE connections and QSFP28 transceivers for 100GbE uplinks . Select the model according to your fiber type, connector and required distance. The transceiver comparison below lists the featured options.

Which transceivers are listed for this switch?

Select the optical module according to the required speed, fiber type, connector and link distance.

Model Port Type Fiber / Connector Supported Reach
DEM-S2801SR 25GbE SFP28 Multimode / Duplex LC Up to 70 m on OM3
Up to 100 m on OM4
DEM-S2810LR 25GbE SFP28 Single-mode / Duplex LC Up to 10 km
DEM-Q2801Q-SR4 100GbE QSFP28 Multimode / MPO Up to 70 m on OM3
Up to 100 m on OM4
DEM-Q2810Q-LR4 100GbE QSFP28 Single-mode / Duplex LC Up to 10 km

Actual reach depends on the selected module, fiber type and complete optical link, including connector and patch-panel losses. Transceivers sold separately.

What is the downlink-to-uplink bandwidth ratio?

The 48 server-facing ports provide up to 1.2 Tbps of aggregate capacity, while the eight uplink ports provide up to 800 Gbps. With all ports operating at their stated maximum speeds and all eight ports used as uplinks, the theoretical downlink-to-uplink ratio is 1.5:1. Using fewer uplinks changes that ratio.

Why are both 2 Tbps and 4 Tbps listed for switching capacity?

They describe the same capacity using different counting conventions: up to 2 Tbps, or up to 4 Tbps full duplex when transmit and receive capacity are counted together. The figures are not additive. The specified packet forwarding rate is up to 2,800 Mpps. Actual throughput depends on traffic patterns, configuration and connected equipment.

What power supplies and fans are included?

The switch includes two hot-swappable power supplies with 1+1 redundancy and four hot-swappable fans with N+1 redundancy . Both power supplies must be powered for power-supply redundancy. Follow the applicable hardware documentation when replacing components.

What rack, airflow and environmental requirements should I plan for?

The switch occupies 1RU in a 19-inch rack and measures 17.32 × 18.50 × 1.73 inches (440 × 470 × 44 mm) . Airflow is front-to-back. The specified operating temperature is 32–113°F (0–45°C), and power consumption is up to 312.6 W. Allow clearance for cabling, ventilation and access to replaceable components.

VIP Pricing Program

Rewarding your affinity for D-Link

Join the D-Link VIP program for access to exclusive perks, including instant rebates on qualifying business-class orders placed through dlink.ca

For IT Professionals, SMBs, Business Owners, and smaller Resellers.

Learn More

For more information on our business-class solution, reseller pricing, distribution availability, and partner program please reach out to our commercial sales team at 
800-354-6522 or
dlinkforbusiness@ca.dlink.com

For support requests and to download assets like Datasheets, Manuals, and Warranty, etc., please visit: support.dlink.com